Football pitch lighting concept prepared in DIALux, including the luminaire list, calculation objects and final illuminance summary for a 500 lx design target.

Project cover

Football pitch project cover in DIALux

Luminaire list

MetricValue
Φ total1,243,680 lm
P total9,475.2 W
Luminous efficacy131.3 lm/W
ManufacturerSITECO
Article No.5XA779116T02FB
Article nameFloodlight FL 11 maxi, PL33T, 4000 K, DALI 2, Ta=10 C

Product data

ParameterValue
Article No.5XA779116T02FB
P1184.4 W
Φ Lamp155460 lm
Φ Luminaire155460 lm
η100.00 %
Luminous efficacy131.3 lm/W
CCT4000 K
CRI70
Product data sheet for the SITECO floodlight

Layout plan

The layout defines the lighting geometry of the football pitch and the placement of eight floodlights at a mounting height of 15m around the field perimeter.

Football pitch luminaire layout plan

Calculation summary

PropertyValue
Calculation surface1
TypePerpendicular illuminance
Height1.6m
E average560 lx
E min354 lx
E max782 lx
Uo0.63
g20.45
IndexCG1
Final perpendicular illuminance result for the football pitch
ABOUT THE PROJECT

This project follows the report structure from the PDF and preserves the sequence of the report pages: cover, table of contents, contacts, luminaire list, product data sheet, layout plan, calculation objects and illuminance result. The report records total power of 9,475.2 W, total luminous flux of 1,243,680 lm, average illuminance of 560 lx, minimum 354 lx, maximum 782 lx and uniformity Uo = 0.63.

DESIGN NOTES
  • 500 lx target
  • 8 floodlights
  • 15.0 m mounting height
  • SITECO FL 11 maxi
  • Uo = 0.63
SPECIFICATION

SITECO Floodlight FL 11 maxi · PL33T LED · 4000 K · DALI 2